Step 9: Tighten the Cables
Apply two wraps of Teon tape around the threads of the unit’s RJ45 jack 1.
(A) in a clockwise direction.
Make sure that the red rubber gasket is still seated in the sealing cap of the 2.
sealing cap/lock nut assembly (B).
Slide the sealing cap/lock nut assembly (B) over the RJ45 jack (A) and 3.
thread onto enclosure. Hand tighten rst, then use a pipe wrench or similar
tool to tighten one more quarter turn.
Caution!
Do not over-tighten!
Tighten the lock nut (C) (Torque 4 N.m/35 in-lbs).4.
Thread the sealing nut (D) onto the sealing cap/lock nut assembly (B) and 5.
tighten (Torque 3 N.m/25 in-lbs).
Caution!
The lock nut (C) on the sealing cap/lock nut assembly (B) must
be fully tightened over the RJ45 connector before the sealing nut
(D) is fully tightened. Otherwise, the Ethernet cable may twist and
damage.